Engine

Engine Power Rating: 1 – 2.5 MW | Invertes power: 1,000 kW / 1,300 kW / 1,500 kW / 1,600 kW / 2,000 kW / 2,500 kW

Battery

Battery Nameplate DC energy (Battery racks/container): 5,016 kWh (6) / 4,180 kWh (5) / 3,344 kWh (4) / 2,508 kWh (3) | DC voltage range: 1,165 – 1,498 VDC | DC nominal voltage: 1,331 VDC | Max C-rate: 0.5C

Electric

Electrical Energy Rating: 2.5 – 5 MWh | Inverter AC Boltage (1,000 kW / 1,300 kW / 1,500 kW / 1,600 kW / 2,000 kW / 2,500 kW): 480 V / 600 V / 690 V / 480 V / 600 V / 800 V

Operational

Operating Conditions 1,000 kW / 1,300 kW / 1,500 kW Overload capacity: Up to 98.5 % | 1,600 kW / 2,000 kW / 2,500 kW Overload capacity: 120% for 10 s | 1,000 kW / 1,300 kW / 1,500 kW Inverter efficiency: Up to 98.5 % | 1,600 kW / 2,000 kW / 2,500 kW Inverter efficiency: Up to 98.7%
Operating Temperature, Maximum DC Block (Battery): -22 °F to 131 °F (-30 °C to 55 °C ) | 1,000 kW / 1,300 kW / 1,500 kW-4 °F to 104 °F (-20 °C to 40 °C) -40 °F (-40 °C) option; power derate above +104 °F (40 °C) | 1,600 kW / 2,000 kW / 2,500 kW: -22 °F to 140 °F (-30 °C to 60 °C) Power derate above +113 °F (45 °C) | 1,600 kW / 2,000 kW / 2,500 kW Altitude before power derate: 3,280 ft (1,000 m)

Performance

Noise Level Frequency 60 Hz | 1,000 kW / 1,300 kW / 1,500 kW: <70 dB @ 9.8 ft (3 m) | 1,600 kW / 2,000 kW / 2,500 kW: <80 dB @ 3.3 ft (1 m)

Dimensions

Dimensions DC Block (Battery): 19.9 ft x 8.0 ft x 9.5 ft (6.1 m x 2.4 m x 2.9 m) | 1,000 kW / 1,300 kW / 1,500 kW Altitude before power derate: 3,280 ft (1,000 m) |
Width 1,000 kW / 1,300 kW / 1,500 kW w/ Controls Enclosure: 4.5 ft (1.4 m) | 1,600 kW / 2,000 kW / 2,500 kW w/ Controls Enclosure: 8.2 ft (2.5 m)
Length 1,000 kW / 1,300 kW / 1,500 kW w/ Controls Enclosure: 5.7 ft (1.7 m) | 1,600 kW / 2,000 kW / 2,500 kW w/ Controls Enclosure: 4.1 ft (1.2 m)
Height 1,000 kW / 1,300 kW / 1,500 kW w/ Controls Enclosure: 7.5 ft (2.3 m) | 1,600 kW / 2,000 kW / 2,500 kW w/ Controls Enclosure: 6.6 ft (2.0 m)

Weights

Weight 5,016 kWh: 99,200 lb (45,000 kg) | 4,180 kWh: 86,900 lb (39,400 kg) | 3,344 kWh: 74,500 lb (33,800 kg) | 2,508 kWh: 62,200 lb (28,200 kg) | 1,000 kW / 1,300 kW / 1,500 kW: 3,520 lb (1,597 kg) | 1,600 kW / 2,000 kW / 2,500 kW: 4,909 lb (2,230 kg)

Features

Features Enclosure Style: Outdoor rated | AC Connection: 3-wire (3P3W) | Power factor: Full 4-quadrant operation | Battery (unit) controller | Ground fault monitoring | BESS control panel | Auxiliary power equipment | Grid forming | Grid following | 4 quadrant operation | NFPA 69 compliant: gas detection and ventilation | NFPA 68 compliant: deflagration panels on all models; NFPA 68 on select models | Dry pipe and sprinkler system | Smoke detector | Audible/visual alarms | Fire alarm control panel | Door mounted Emergency-Stop | UPS capable of 24 hrs in standby and 2 hrs in alarm | DC Block: Lifting points | Inverter: Lifting eyebolts | Controls Cabinet: Lifting eyebolts and forklift pockets