2025 Generac Mobile Stationary Battery Energy Storage SBE500

2025 Generac Mobile Stationary Battery Energy Storage SBE500

Swipe to View More

  • Year 2025
  • Make Generac Mobile
  • Model Stationary Battery Energy Storage
2025 Generac Mobile Stationary Battery Energy Storage SBE500

2025 Generac Mobile Stationary Battery Energy Storage SBE500

2025 Generac Mobile Stationary Battery Energy Storage SBE500

Engine

Engine Power Power Rating: 125 kW / 250 kW / 500 kW | SBE-599-125: 125 kW / 500 kWh | SBE-599-250: 250 kW / 500 kWh | SBE-599-500: 500 kW / 500kWh | SBE-576–125/SBE-864-125: 125kW | SBE-576-250/SBE-864-250: 250 kW

Battery

Battery Capacity, Nominal SBE-599-125/SBE-599-250/SBE-599-500 Nominal voltage: 998.4 VDC | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 Nominal Voltage Range: 1,152 VDC | SBE-599-125/SBE-599-250/SBE-599-500 Nominal AC voltage: 480 V | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 Nominal AC voltage: 480 V
Battery Energy Rating: 576–864 kWh | SBE-599-125/SBE-599-250/SBE-599-500 AC connection: 3-wire (3P3W) | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 AC connection: 3-wire (3P3W)

Electric

Electrical SBE-599-125/SBE-599-250/SBE-599-500 Nameplate DC energy: 599 kWh | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 Nameplate DC energy: 576 kWh/864 kWh/576 kWh/864 kWh | SBE-599-125/SBE-599-250/SBE-599-500 DC voltage range: 874-1,123 VDC | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 DC voltage range: 1,008-1,296 VDC

Operational

Operating Conditions SBE-599-125 Overload capacity: 120%, 10s | SBE-599-250 SBE-599-500 Overload capacity: 110%, 10 min; 125%, 10 s | SBE-576–125 SBE-864-125 Ovwerload capacity: 120%, 10s | SBE-576-250 SBE-864-250 Overload capacity: 110%, 10 min 125%, 10 s | SBE-599-125 Inverter efficiency: Up to 98.7% | SBE-599-250/SBE-599-500 Inverter efficiency: Up to 98.4% | SBE-576–125/SBE-864-125 Inverter efficiency: Up to 98.7% | SBE-576-250/SBE-864-250 Inverter efficiency: Up to 98.7%
Operating Temperature, Maximum -13 °F to 113 °F -25 °C to 45 °C

Performance

Noise Level SBE-599-125/SBE-599-250/SBE-599-500 Frequency: 60 Hz | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 Frequency: 60 Hz | Noise (approx.): <65 dB @ 3.3 ft (1 m)

Dimensions

Dimensions Enclosure Style: Custom 10 ft | SBE-599-125/SBE-599-250: 2.3 ft x 8 ft x 9.6 ft (3.8 m x 2.4 m x 2.9m) | SBE-599-500: 13.8 ft x 8 ft x 9.6 ft (4.2 m x 2.4 m x 2.9m) | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250: 12.3 ft x 8 ft x 9.6 ft (3.8 m x 2.4 m x 2.9 m) | Altitude before derate: 3,280 ft (1,000 m)

Weights

Weight SBE-599-125: 24,944 lb (11,314 kg) | SBE-599-250: 25,500 lbs (11,567 kg) | SBE-599-500: 27,062 lb (12,275 kg) | SBE-576–125: 22,042 lb (9,998 kg) | SBE-864-125: 27,719 lb (12,573 kg) | SBE-576-250: 22,590 lb (10,247 kg) | SBE-864-250: 26,959 lb (12,228 kg)

Features

Features SBE-599-125/SBE-599-250/SBE-599-500 Power factor: Full 4-quadrant operation | SBE-576–125/SBE-864-125/SBE-576-250/SBE-864-250 Power factor: Full 4-quadrant operation | Enclosure: NEMA 3R (Outdoor) | Auxiliary load panel | Lighting | BESS controller panel | Ground fault monitoring | Battery (unit) controller | Door open alarm switch | Dynamic transfer | Grid forming | Grid following | 4 quadrant operation | THD < 2% | Load imbalance capable | Electric reheat with humidity control | Gas (H2) and dual zone smoke detectors | Audible/visual alarms for gas, smoke | Dry solution fire suppression | Door mounted E-Stop (remote available) | NFPA 69 compliant: dedicated H2 fan, dedicated UPS for 2 hr H2 fan runtime and 24 hr monitoring | NFPA 68 compliant: deflagration panels on all models; NFPA 68 compliance on select models | NEMA 3R | Insulated enclosure and doors | Reinforced cable cutouts entry points | Corner cast lifting provisions
Construction Material Structural steel base

Product Photography