2025 Generac Mobile Industrial Transfer Switches psts-2000-5000a-bypass-isolation
- Year 2025
- Make Generac Mobile
- Model Industrial Transfer Switches
2025 Generac Mobile Industrial Transfer Switches psts-2000-5000a-bypass-isolation
The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection. These distinctive Generac models combine an automatic transfer switch with an isolation mechanism and a manual bypass switch to provide redundant power transfer and re-transfer capability for critical-need applications requiring consistent and uninterrupted power to the load.
Features may include:
- 100 – 5000 Amp
- Open with Time Delay Neutral or In-Phase Transfer
- Closed Transition
- Bypass Isolation
- Contactor, Power Frame, or Molded Case Breaker
- 2, 3, 4 Pole
- NEMA 1, 12, 3R, 4 & 4X
- UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
- Microprocessor Based Control
- Two Wire Start – Any Generator Controller
- Service Entrance and Non-Service Entrance Rated
Electric
Electrical
Fixed-Mount Open with Inphase or Delayed Transition Amperes: 2,000/2,500–3,200 | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Poles: 3-4/3-4 | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cy/Al / (9) 1/0-750 MCM Cu/Al | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | Drawout Open with Inphase or Delayed Transition Amperes: 2,000-2,500-3,200 | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Poles: 3-4/3-4 | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM / (9) 1/0-750 MCM | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Neutral Connection: (24) 4/0-500 MCM / (36) 4/0-500 MCM | UL 1008 Withstand and Closing Ratings Ampere Rating: 2,00/2,500/3,000/3,200/4,000/5,000 | UL 1008 Withstand and Closing Ratings 2,00/2,500/3,000/3,200/4,000/5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600V-30 Cycle 600V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA/
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Height
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm)
Width
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 32.0 in (812 mm)/44.0 in (1,117 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 32.0 in (812 mm) / 44.0 in (1,117 mm)
Depth, Maximum
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 48.0 in (1,219 mm)-63.0 in (1,600 mm)/48.0 in (1,219 mm)-63.0 in (1,600 mm) / 48.0 in (1,219 mm)-63.0 in (1,600 mm)/48.0 in (1,219 mm)-63.0 in (1,600 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm) / 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm)
Weights
Weight
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 1,050 lbs (477 kg)-1,600 lbs (727 kg)/1,250 lbs (568 kg)-1,800 lbs (818 kg) / 1,900 lbs (864 kg)- 2,400 lbs (1,091 kg)-2,000 lbs (909 kg)-2,500 lbs (1,136 kg) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 1,600 lbs (727 kg)-2,100 lbs (955 kg)/1,900 lbs(864 kg)-2,400 lbs (1,091 kg) / 2,500 lbs (1,136 kg)-3,000 lbs (1,364 kg)/2,800 lbs (1,273 kg)-3,300 lbs (1,500 kg)
Features
Features
Fixed-Mount Open with Inphase or Delayed Transition 2,000-2,500-3,200 Enclosure Type 8NEMA): 1-3R/1-3R / 1-3R/1-3R | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | High Withstand and Closing Ratings | Safe Manual Transfer Under Load | Front Access | Cable or Bus Entry is Top, Bottom or Both | Isolated Compartments for Improved Safety | Mimic Diagram with Source Available and Connected LED Indication | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Field-Selectable Multi-Tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Modbus® RTU | ATC-900 Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On