The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection.

Features may include:

  • Standard — Provides fast transfers and is an economical and easy-to-use choice for most facilities.
  • Service Entrance — Provides a disconnect that interrupts excessive voltage and allows for manually disconnecting your facility from the electrical utility. Rated for full load transfers in critical operating, emergency, legally required, and optional power systems.
  • Bypass Isolation — Designed for transfer switch applications where maintenance must be performed while maintaining continuous power to the load.
  • Manual – Designed for applications having a need for a mobile generator, providing reliable and easy-to-use connections for safe and quick backup power connection.
  • 100 – 5000 Amp
  • Open with Time Delay Neutral or In-Phase Transfer
  • Closed Transition
  • Bypass Isolation
  • Contactor, Power Frame, or Molded Case Breaker
  • 2, 3, 4 Pole
  • NEMA 1, 12, 3R, 4 & 4X
  • UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
  • Microprocessor Based Control
  • Two Wire Start – Any Generator Controller
  • Service Entrance and Non-Service Entrance Rated

Electric

Electrical Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount Amperes: 1,200-2,000/2,500-3,200 | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,000/2,500-3,200 Poles: 3-4/3-4 | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout Amperes: 1,200-2,000/2,500-3,200 | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200–2,000/2,500-3,200 Poles: 3-4/3-4 | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200-2,000/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200-2,000/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 1,200/2,000/2,500/3,000/3,200/4,000/5,000 | UL 1008 Withstand and Closing Ratings 1,200/2,000/2,500/3,000/3,200/4,000/5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600 V-30 Cycle 600 V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA

Operational

Operating Temperature, Maximum -4 ° to 158 °F (-20 ° to 70 °C)

Dimensions

Height Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200: 90.0 in (2286 mm)/90.0 in (2286 mm) | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200–2,000/2,500-3,200: 90.0 in (2286 mm)
Width Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200: 32.0 in (813 mm)/ 44.0 in (1118 mm) | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200–2,000/2,500-3,200: 32.0 in (813 mm)/44.0 in (1118 mm)
Depth, Maximum Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200: 48.0 in (1219 mm)-63.0 in (1600 mm) / 48.0 in (1219 mm)-63.0 in (1600 mm) | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200–2,000/2,500-3,200: 60.0 in (1,524 mm)-75.0 in (1905 mm)/60.0 in (1,524 mm)-75.0 in (1905 mm) / 60.0 in (1,524 mm)-75.0 in (1905 mm)/60.0 in (1,524 mm)-75.0 in (1905 mm)

Weights

Weight Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200: 1,050 lbs (477 kg)-1,600 lbs (727 kg)-1,250 lbs (568 kg)-1,800 lbs (818 kg) / 1,900 lbs (864 kg)- 2,400 lbs (1,090 kg)-2,000 lbs (909 kg)- 2,500 lbs (1,136 kg) | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200-2,000/2,500-3,200: 1,600 lbs (727 kg)-2,100 lbs (953 kg)-1,900 lbs (864 kg)-2,400 lbs (1,091 kg) / 2,500 lbs (1,136 kg)-3,000 lbs (1,364 kg)-2,800 lbs (1,273 kg)-3,300 lbs (1,500 kg)

Features

Features Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Fixed Mount 1,200-2,00/2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Service Entrance Rated, Power Frame Type, Open and Delayed Transition, 1,200 – 3,200 A, Drawout 1,200–2,000/2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | High Withstand and Closing Ratings | Safe Manual Transfer Under Load | Front Access | Cable or Bus Entry is Side, Rear, Top and Bottom | Isolated Compartments for Improved Safety | ATC-900 Controller | Mimic Diagram with Source Available and Connected LED Indication | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Field-Selectable Multi-Tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Modbus® RTU | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. /Source-2 Position, 1-N.O. and 1-N.C. | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On