2025 Generac Mobile Industrial Transfer Switches 671-1000a-non-se-rated-closed-transition
- Year 2025
- Make Generac Mobile
- Model Industrial Transfer Switches
2025 Generac Mobile Industrial Transfer Switches 671-1000a-non-se-rated-closed-transition
New to the Generac industrial transfer switch line is the TX Series. The TX Series switches are both Generac designed and built in house with exceptional features that meet, and exceed, any application needs. These transfer switches have some of the highest withstand and closing ratings (WCR). In addition, these switches offer no PPE needed for controller use, firmware updates, or data downloads when the enclosure door is installed.
Electric
Electrical
1000A 2 & 3 Pole - 1000 4 Pole Normal 75 °C Wire: (4) 750 - 4/0 | 1000A 2 & 3 Pole - 1000 4 PoleStandby Source 75 °C Wire: (4) 750 - 4/0 | 1000A 2 & 3 Pole - 1000 4 PoleLoad 75 °C Wire: (4) 750 - 4/0 | 1000A 2 & 3 Pole - 1000 4 Pole Neutral Connection: (12) 750 -1/0 | 1000A 2 & 3 Pole - 1000 4 Pole Ground Connection: (13) 600 - #4 or (26) 250 - 1/0 | Ampere Rating: 1000 | 3-Cycle Rating: 100 kA | 30-Cycle Rating (Class L): 65 kA | Fuse Rating (Class L): 200 kA | Fuse Size (Class L): 2000 A | Voltage: 600 V
Operational
Operating Temperature, Maximum
-4° to 158°F (-20° to 70°C)
Dimensions
Dimensions
1000A 2 & 3 Pole: 18.55 in (471.2 mm) | 1000 4 Pole: 15.96 in (405.4 mm) | 1000A 2 & 3 Pole - 1000 4 Pole: 2.59 in (65.9 mm) / 1.20 in (30.5 mm) / 25.78 in (654.7 mm) / 27.17 in (690.1 mm) / 28.41 in (721.6 mm) / 29.81 in (757.3 mm) / 62.60 in (1590 mm) / 63.99 in (1625.3 mm) / 8.91 in (226.3 mm) / 6.97 in (177 mm) / 2.50 in (63.4 mm) / 4.44 in (112.8 mm)/ 6.97 in (177 mm) / 8.91 in (226.3 mm)
Weights
Weight
1000A 2 & 3 Pole: 2–Pole: 600 lbs (272.2 kg) / 3–Pole 650 lbs (294.8 kg) | 1000 4 Pole: 700 lbs (317.5 kg)
Features
Features
Floor Mounted, Wall Secured | Cable Entry is Top or Bottom | Double-Throw, Stored Energy Transfer Mechanism | Graphical LCD-Based Display for Programming, System Diagnostics, and Help Menu Display Mimic | Diagram with Source Available and Connected LED Indicator | Method of Transfer: Closed Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU Communications | TXC 100 Controller | Removable Bottom Plates for Ease of Entry | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on All 3R Enclosures | Auxiliary Output Includes: Two Wire Start, Signal Before Transfer, Fault, and a Programmable Relay Output | Auxiliary Input Includes: Permissive Inputs (24VDC) | General Alarm Indication | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Switch Position Indication (4 Form C) | Signal Before Transfer (Elevator) | General Alarm | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency (Demand Response) | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for Up to 60 Minutes in the Event of No Source Availability | Generator Battery Backup for Controller | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash | All Amp Nodes Offered with Delayed Transition | Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly
Warranty
Warranty
2 Year Standard Warranty