New to the Generac industrial transfer switch line is the TX Series. The TX Series switches are both Generac designed and built in house with exceptional features that meet, and exceed, any application needs. These transfer switches have some of the highest withstand and closing ratings (WCR). In addition, these switches offer no PPE needed for controller use, firmware updates, or data downloads when the enclosure door is installed.
Electric
Electrical
100A Non Ser Type 1/100A Non Ser Type 3R Normal 75 ° C Wire: (1) 2/0 - 14 | 100A Non Ser Type 1/100A Non Ser Type 3R Standby Source 75 °C Wire: (1) 2/0 - 14 | 100A Non Ser Type 1/100A Non Ser Type 3R Load 75 °C Wire: (1) 2/0 - 14 | 100A Non Ser Type 1/100A Non Ser Type 3R Neutral Connection: (5) 2/0 - 14 | 100A Non Ser Type 1/100A Non Ser Type 3R Ground Connection: (2) 1/0 - 14 | 150A Non Ser Type 1/150A Non Ser Type 3R/200A Non Ser Type 1/200A Non Ser Type 3R Normal 75 ° C Wire: (1) 250 - 6 | 150A Non Ser Type 1/150A Non Ser Type 3R/200A Non Ser Type 1/200A Non Ser Type 3R Standby Source 75 °C Wire: (1) 250 - 6 | 150A Non Ser Type 1/150A Non Ser Type 3R/200A Non Ser Type 1/200A Non Ser Type 3R Load 75 °C Wire: (1) 250 - 6 | 150A Non Ser Type 1/150A Non Ser Type 3R/200A Non Ser Type 1/200A Non Ser Type 3R Neutral Connection: (4) 350 - 6 | 150A Non Ser Type 1/150A Non Ser Type 3R/200A Non Ser Type 1/200A Non Ser Type 3R Ground Connection: (2) 250 - 6 | 300A Non Ser Type 1/300A Non Ser Type 3R/400A Non Ser Type 1/400A Non Ser Type 3R Normal 75 ° C Wire: (1) 600 - 4 or (2) 250 - 1/0 | 300A Non Ser Type 1/300A Non Ser Type 3R/400A Non Ser Type 1/400A Non Ser Type 3R Standby Source 75 °C Wire: (1) 600 - 4 or (2) 250 - 1/0 | 300A Non Ser Type 1/300A Non Ser Type 3R/400A Non Ser Type 1/400A Non Ser Type 3R Load 75 °C Wire: (1) 600 - 4 or (2) 250 - 1/0 | 300A Non Ser Type 1/300A Non Ser Type 3R/400A Non Ser Type 1/400A Non Ser Type 3R Neutral Connection: (5) 600 MCM - 4 or (10) 250 MCM - 1/0 | 300A Non Ser Type 1/300A Non Ser Type 3R/400A Non Ser Type 1/400A Non Ser Type 3R: (2) 250 - 6 | Ampere Rating: 100/150/200/300/400 | Specific Breaker: 42 kA/ 42kA/ 42 kA/ 65 kA/ 65 kA | 3-Cycle Rating: 22kA/22kA/22kA/35kA/35kA | Fuse Rating (Class J): 200 kA | Fuse Size: 200 A/200 A/200 A/400 A/400 A
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Dimensions
100A Non Ser Type 1: 35.6 in (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 12.0 in (305 mm) / 8.9 in (226 mm) / 9.9 in (252 mm) / 18.5 in (471 mm) / 13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm) / 5.8 in (148 mm) / 5.8 in (148 mm) / 3.1 in (79 mm) | 100A Non Ser Type 3R: 35.6 in (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 13.9 in (355 mm) / 8.9 in (226 mm) / 9.9 in (252 mm) / 18.5 in (471 mm) / 13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm) / 5.8 in (148 mm) / 5.8 in (148 mm) / 3.1 in (79 mm) | 150A Non Ser Type 1: 35.6 in (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 12.0 in (305 mm) / 9.3 in (236 mm) / 10.3 in (262 mm) / 18.1 in (460 mm) / 13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm) / 6.0 in (153 mm) / 6.0 in (153 mm) / 3.3 in (84 mm) | 150A Non Ser Type 3R: 35.6 in (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 12.0 in (305 mm) / 9.3 in (236 mm) / 10.3 in (262 mm) / 18.1 in (460 mm) / 13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm) / 6.0 in (153 mm) / 6.0 in (153 mm) / 3.3 in (84 mm) | 200A Non Ser Type 1: 35.6 (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 12.0 in (305 mm) / 9.3 in (236 mm) / 10.3 in (262 mm) / 18.1 in (460 mm) /13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm)/ 6.0 in (153 mm) / 6.0 in (153 mm) / 3.3 in (84 mm) | 200A Non Ser Type 3R: 35.6 in (903 mm) / 31.7 in (806 mm) / 21.2 in (538 mm) / 12.0 in (305 mm) / 9.3 in (236 mm) / 10.3 in (262 mm) / 18.1 in (460 mm) / 13.7 in (348 mm) / 12.4 in (315 mm) / 1.7 in (44 mm) / 1.7 in (44 mm) / 6.0 in (153 mm) / 6.0 in (153 mm) / 3.3 in (84 mm) | 300A Non Ser Type 1: 51.4 in (1,305 mm) / 47.5 in (1,206 mm) / 24.2 in (614 mm) / 12.0 in (305 mm) / 9.7 in (246 mm) / 11.5 in(292 mm) / 20.3 in (516 mm) / 14.8 in (377 mm) / 13.1 in (311 mm) / 2.3 in (59 mm) / 2.3 in (59 mm) / 6.5 in (166 mm) / 6.5 in (166 mm) / 3.3 in (84 mm) | 300A Non Ser Type 3R: 51.4 in (1,305 mm) / 47.5 in (1,206 mm) / 24.2 in (614 mm) / 12.0 in (305 mm) / 9.7 in (246 mm) / 11.5 in (292 mm) / 20.3 in (516 mm) / 14.8 in (377 mm) / 13.1 in (311 mm) / 2.3 in (59 mm) / 2.3 in (59 mm) / 6.5 in (166 mm) / 6.5 in (166 mm) / 3.3 in (84 mm) | 400A Non Ser Type 1: 51.4 in (1,305 mm) / 47.5 in (1,206 mm) / 24.2 in (614 mm) / 12.0 in (305 mm) / 9.7 in (246 mm) / 11.5 in (292 mm) / 20.3 in (516 mm) / 14.8 in (377 mm) / 13.1 in (311 mm) / 2.3 in (59 mm) / 2.3 in (59 mm) / 6.5 in (166 mm) / 6.5 in (166 mm) / 3.3 in (84 mm) | 400A Non Ser Type 3R: 51.4 in (1,305 mm) / 47.5 in (1,206 mm) / 24.2 in (614 mm) / 12.0 in (305 mm) / 9.7 in (246 mm) / 11.5 in (292 mm) / 20.3 in (516 mm) / 14.8 in (377 mm) / 13.1 in(311 mm) / 2.3 in (59 mm) / 2.3 in (59 mm) / 6.5 in (166 mm) / 6.5 in (166 mm) / 3.3 in (84 mm)
Weights
Weight
100A Non Ser Type 1: 105.6 lbs (48 kg ) | 100A Non Ser Type 3R: 110.0 lbs (50 kg) | 150A Non Ser Type 1: 116.6 lbs (53 kg) | 150A Non Ser Type 3R: 121.0 lbs (55 kg) | 200A Non Ser Type 1: 116.6 lbs (53 kg) / 200A Non Ser Type 3R: 121.0 lbs (55 kg) | 300A Non Ser Type 1: 173.8 lbs (79 kg) | 300A Non Ser Type 3R: 178.2 lbs (81 kg) | 400A Non Ser Type 1: 173.8 lbs (79 kg) | 400A Non Ser Type 3R: 178.2 lbs (81 kg)
Features
Features
Small Footprint, Results in Easy Mounting and Installation for Reduced Time and Costs | Cable Entry is Top or Bottom | Double-Throw, Stored Energy Transfer Mechanism | Can be Electrically Isolated while Energized | Graphical LCD-Based Display for Programming, System Diagnostics and Help Menu Display Mimic | Diagram with Source Available and Connected | LED Indicator | Method of Transfer: Open with Inphase Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU | TXC 100 Controller | Removable Top and Bottom Plates for Ease of Entry | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on All 3R Enclosures | Auxiliary Output Includes: Two Wire Start, Signal Before Transfer, Fault, and a Programmable | Relay Output | Auxiliary Input Includes: Permissive Inputs | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Signal Before Transfer (Elevator) | General Alarm | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency (Demand Response) | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for up to 60 Minutes in the Event of No Source Availability | Generator Battery Backup for Controller | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash | All Amp Nodes Offered with Delayed Transition | Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly